| Methods of Connection and Setup - Mobile Phone |
| |
|
Characteristics |
|
|
MicroLog can record the input from a handsfree kit or a mobile telephone. |
|
| |
|
|
Method of Connection |
| |
Use the 3.5mm input jacks to detect the signals from the handsfree kit of mobile telephone. The mobile phone may need a special cable (contact your provider for a compatible cable). |
|
| |
|
| |
|
|
Software Setup |
| |
Please check the following settings in "Setup" menu. |
|
1. |
Set "Audio-In" to "OFF" |
|
2. |
Adjust A and W values under MVOX based on your need. Default MVOX: A = 04 W = 04 |
|
| |
Note: Lower AVOX, MVOX values means high sensitivity. |
|
3. |
Set "VOX Off TM" to your desired value. Default value is 5 seconds. Please refer to A.2 (What is "VOX off TM") for explanation on the values of "VOX off TM" |
|
| |